LCO2 Storage Tanks/Vacuum Insulated

LCO2
CoHSP series horizontal cryogenic storage tanks are designed and manufactured for CO2 and N2O services, inner vessels of which are of stainless steel. CoHSP series pressure containing vessels are insulated with a vacuum insulating material such as perlite. Vacuum insulated vessels are fitted with refrigeration units and pressure building vaporizer, depending on the customer requirement.

EXPLORE LCO2 STORAGE TANKS

CoHSP series horizontal cryogenic storage tanks are designed and manufactured for CO2 and N2O services, inner vessels of which are of stainless steel.

CoHSP series pressure containing vessels are insulated with a vacuum insulating material such as perlite. Vacuum insulated vessels are fitted with refrigeration units and pressure building vaporizer, depending on the customer requirement. The refrigeration unit condenses the boil off gas resulted from heat input.

THE HIGHLIGHTS OF ISISAN TANKS ARE

  • CoHSP series tanks are vertical, stationary, pressure vessels with vacuum insulation for long-term storage of cold liquids with high performance heat insulation and low evaporation rate.
  • High operational reliability provided with back pressure check valve on vent side and high pressure due the faulty operations is prevented.
  • In addition to our standard range of tanks, ISISAN can provide you a wide range of tailor made storage solutions up to 190,000 lt with a Maximum Allowable Working Pressure of 22/24 bars or other pressures as required.
  • ISISAN bulk tanks are designed and manufactured in accordance with and conforming to EC directive PED 2014/68/EU and EN 13458 or other national pressure vessel codes as required.
  • ISISAN’s cryogenic tank manufacturing facility is ISO 9000 approved to assure the best quality in all aspects of our operation.
  • The support legs used are calculated according to UBC, Eurocode standards to resist high wind and earthquake loads.
  • Carefully designed stainless steel pipe work to reduce filling operation time. Appropriate bending of stainless steel pipe work means fewer connections, minimizing potential leaks, higher operability and less servicing.
  • High quality stainless steel pressure gauge, a differential pressure contents gauge or load cell is standard; with optional switches, transmitter and/or telemetry unit.
  • High performance safety system with dual relief valves by the diverter valves as standard.
  • Easily accessible valves and safety relief valve outlets directed away from the operating area enables safe operation.
  • Rugged internal supports for safe transportation by road, container or rail.

SPECIFICATION

 Design Code EN 13458 – PED 97/23/EC
 Max. Allowable Working Pressure 22 bar
 Design Temperature -196°C
 Inner Vessel Material Stainless Steel (According to EN 10028-7)
 Outer Vessel Material Carbon Steel (According to En 10025/EN10028-3)
 Insulation Perlite & Vacuum
Air Gas Standard Storage Tanks Dimensions

22 Bar Vacuum Insulated CO2 Storage Tanks

MAWPGross CapacityNet Capacity
(%95 Filling)
Daily Evap.
Rate (CO2)
0DBLWHEmpty
Weight
barlitersliters% / daymmmmmmmmmmkg
2225000237500.122750774084903030287014000
30000285000.112750888096303030287017000
35000332500.10275010130108803030287019500
43000408500.10250014110145602770270023500
50000475000.10265014200146502920270026000
Data given on the table are nominal volumes and actual capacity may vary from these due to manufacturing tolerances.

P&ID